Hensikten med tilstandskontroll er å maksimere Life Time Profit for vindparken ved å unngå produksjonstap og følgeskader forårsaket av feil på vitale deler, primært generator lager, gearkassse og hovedlager.

Intelligent tilstandskontroll for vindparker

The SPM system is very sensitive and provides an early warning of a component’s deteriorating operating condition. This allows planned maintenance and replacements with the shortest possible downtime.

Monitored parameters are shock pulses and vibration, the most reliable and specific condition indicators, at preset intervals. The system measures signal amplitudes, provides shock and vibration spectra and, most importantly, individual values on specific fault symptoms showing the state of a bearing inner ring, a gearwheel, etc.

The primary message that reaches the wind plant operator is an easy to understand condition value, coded green - good condition, yellow - alert and red - bad condition, together with a description of its most probable cause.

SPM provides reliable and easy to handle condition information, technically and economically adjusted to the requirements of each individual plant.

Windmill diagram

1. Generator

Recommended methods: SPM HD® and EVAM measurement of both shock and vibrations.
Reason: Reduced bearing condition is the most common failure cause, together with misalignment.
Remark: Reliable, ample pre-warning time.

2. Gearbox

Recommended method: SPM HD® and EVAM
Reason: Coupling and gear-related problems on the high speed side of the gearbox, shock pulse measurements for bearing condition on the slow rotating side of the gearbox.
Remark: Gearboxes are complex units that ned different measuring techniques to cover all faults. RPM is calculated from the rotor speed.

3. Main bearings

Recommended methods: SPM HD®, spectrum and time signal analysis.
Reason: The proper method for slow rotating bearings.
Remark: The RPM measurement is very important for slow rotating parts.